Commercial construction in Tampa Bay presents unique challenges: high wind loads, extreme heat, humidity, UV exposure, and corrosive coastal conditions. Exterior wall systems must be engineered not only for appearance, but for structural performance, energy efficiency, and lifecycle durability.
Tampa Commercial Siding specializes exclusively in commercial and industrial metal siding systems. We work directly with general contractors, construction managers, and project stakeholders to install panel systems that meet Florida Building Code (FBC) requirements and align with engineered design intent.
Our focus is not residential aesthetics — it is performance, compliance, and execution.
We provide installation of engineered metal panel systems for new construction and retrofit applications across industrial, retail, multifamily, institutional, and specialty commercial projects.
PBR (Purlin Bearing Rib) panels are structural metal panels designed to span framing members without continuous sheathing. These systems are widely used in:
- Warehouses and distribution centers
- Manufacturing and industrial facilities
- Commercial roof and wall assemblies
Key performance characteristics:
Deep bearing ribs for increased load capacity
Compatibility with steel framing and CMU substrates
Engineered fastening patterns for wind uplift resistance
Available in multiple gauges and high-performance finishes
R Panel systems are exposed-fastener metal panels commonly specified for light industrial and commercial applications where cost control and installation efficiency are critical. Typical applications include:
- Light industrial buildings
- Agricultural and utility structures
- Commercial storage and service buildings
System advantages:
Predictable installation timelines
Code-compliant wind performance when installed per spec
Compatibility with insulation and liner panel systems
“Installation met specified wind load requirements and was completed on schedule with proper coordination during inspections.”
Tom
General Contractor
“Panels were installed plumb, square, and in accordance with submitted shop drawings.”
Craig
Project Manager
“Good communication, clean execution, and adherence to project specifications. Mike and his team were great to work with.”
Caroline
Facility Manager
Metal siding systems offer superior performance in Tampa’s subtropical and coastal environment, where traditional cladding materials often fail prematurely. Our installed systems are selected and detailed to address:
- High-velocity hurricane wind loads
- Salt-air corrosion exposure
- UV radiation and heat gain
- Moisture intrusion and condensation control
When properly engineered and installed, commercial metal panels provide consistent long-term performance with minimal maintenance requirements.
Performance Advantages of Commercial Metal Siding Systems
Metal siding systems reduce lifecycle cost.
Improve building envelope performance.
Minimize long-term operational risk.
PBR panels are designed for projects where structural capacity and spanning capability are required. The panel profile includes bearing legs that allow attachment directly to purlins or girts.
Typical specifications include:
- Panel depth: ~1.25 inches
- Gauge range: 26ga to 18ga
- Substrates: Galvanized steel or Galvalume®
- Finish systems: SMP or PVDF (Kynar®)
These systems are commonly specified for HVHZ and non-HVHZ commercial applications when installed per engineered fastening schedules.
R Panels provide a balance of performance and economy for large-scale commercial projects.
Key characteristics:
- Exposed fastener attachment
- Ribbed profile for strength
- Compatible with insulation and liner panels
- Rapid installation for schedule-sensitive projects
R Panels are frequently used where value engineering is required without sacrificing code compliance.
The durability of a metal siding system depends on more than panel material alone. Performance is driven by:
- Proper substrate preparation
- Engineered fastener spacing
- Flashing and penetration detailing
- Moisture and condensation control
Correctly installed systems protect structural components, insulation, and interior finishes over decades of service.
Metal siding systems support modern energy codes when integrated with continuous insulation (CI) and proper air barrier detailing.
Typical performance ranges:
- No CI: R-4 to R-6
- 1.5" CI: R-10 to R-12
- 3" CI: R-18 to R-22
High-reflectivity finishes further reduce solar heat gain, improving HVAC efficiency in cooling-dominated climates like Florida.
Our installation process aligns with commercial construction standards:
- Pre-Construction Review
Substrate conditions, framing alignment, and design criteria evaluated.
- Submittals & Coordination
Panel profiles, finishes, and attachment methods coordinated with project documents.
- Installation & Quality Control
Panels installed per approved details; fasteners torqued to specification.
- Inspection & Close-Out
Final walkthrough and documentation provided as required.
The durability of a metal siding system is determined by:
- Material & Coatings
High-performance zinc/aluminum coatings
PVDF finishes for UV stability
- Attachment & Detailing
Engineered fastener patterns
Flashing and sealant specifications
Rain screen and condensation control
- Lifecycle Metrics
Corrosion resistance per ASTM standards
Finish retention ratings
Properly engineered and installed systems reduce maintenance, weather infiltration, and service interruptions.
Mon-Sun: 7am - 7pm
© Copyright 2026 . All Rights Reserved.
Terms & Conditions | Privacy Policy
Zip codes we serve:
33592,33647,33637,33584,33646,33565,33583,33543,33617,33550,33620,33524,33527,33566,33610,33559,33510,33563,33541,33587,33539,33508,33509,33564,33542,33549,33594,33540,33613,33612,33545,33595,33604,33548,33544,33511,34639,33618,33619,33603,33530,33605,33688,33596,33558,33849,33689,33694,33574,33567,33601,33622,33623,33630,33631,33633,33650,33655,33660,33672,33673,33674,33675,33677,33679,33680,33681,33682,33684,33685,33686,33687,33602,33624,33614,33576,33810,33815,33569,33606,33568,34637,33525,33607,33811,33664,33578,33625,33634,33609,33629,33526,33806,33804,33534,33805,33556,33802,33809